EC Line EC-2D Spécifications Page 85

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 192
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 84
78
UPC/EAN/JAN Supplemental Redundancy
With Auto discriminate UPC/EAN/JAN Supplemental selected, this option
adjusts the number of times a symbol without supplemental is decoded before
transmission. The range is from two to thirty times. Five or above is
recommended when decoding a mix of UPC/EAN/JAN symbols with and
without supplemental, and the auto discriminate option is selected. The default
is set at 10.
Scan the bar code below to set a decode redundancy value. Next, scan two
numeric bar codes in Appendix D, Numeric Bar Codes. Single digit numbers
must have a leading zero. To correct an error or change a selection, scan
Cancel.
UPC/EAN/JAN Supplemental Redundancy
Transmit UPC-A Check Digit
The check digit is the last character of the symbol used to verify the integrity of
the data. Scan the appropriate bar code below to transmit the bar code data
with or without the UPC-A check digit. It is always verified to guarantee the
integrity of the data.
< Transmit UPC-A Check Digit >
Do Not Transmit UPC-A Check Digit